DC Bias Current Source

DC Bias Current Source, when coupled with an LCR Meter or Impedance Analyzer, allows for the analysis of saturation characteristics in components such as inductors, coils, ferrite cores, and iron cores. It enables precise verification of magnetic saturation current (Isat) and temperature rise current (Irms).

Model 6243H: Single unit output of 40A, stackable up to 16 units, with a maximum combined output of 640A, and a frequency response of 100Hz-10MHz.

Model 6243: Single unit output of 40A, stackable up to 8 units, with a maximum combined output of 320A, and a frequency response of 100Hz-10MHz.

Model 6223: Single unit output of 20A, stackable up to 6 units, with a maximum combined output of 120A, and a frequency response of 100Hz-10MHz.

Model 6240A: Single unit output of 40A, stackable up to 8 units, with a maximum combined output of 320A, and a frequency response of 100Hz-3MHz.

Model 6220: Single unit output of 20A, stackable up to 6 units, with a maximum combined output of 120A, and a frequency response of 100Hz-3MHz.

Model 6210: Single unit output of 10A, stackable up to 6 units, with a maximum combined output of 60A, and a frequency response of 100Hz-3MHz.
DC Bias Current Source
DC Bias Current Source|6243H/6243 (40A)
DC Bias Current Source
6243H/6243 (40A)
  • Up to 10MHz
  • Each individual unit can output DC Bias Current 40A (Max.640A)
  • Control by the LCR Meter or Impedance Analyzer
The 6243H/6243 DC Bias Current Source is designed for performing magnetic saturation current (Isat) and temperature rise current analysis (Irms) on inductors. It provides a single output current of 40A. To conduct such analysis, you have the option to purchase the system along with the 6632 Impedance Analyzer or the 6355/6356 LCR Meter. If you choose the 6632 Impedance Analyzer, it has a frequency range of 100Hz-10MHz and can handle a maximum output current of 640A using 16 units.For the 6355 LCR Meter, it has a frequency range of 100Hz-200kHz and can handle a maximum output current of 640A using 16 units.The 6356 LCR Meter has a frequency range of 100Hz-500kHz and can handle a maximum output current of 640A using 16 units.
Inquiry Compare
DC Bias Current Source|6223 (20A)
DC Bias Current Source
6223 (20A)
  • Up to 10MHz
  • Each individual unit can output DC Bias Current 20A (Max.120A)
  • Control by the LCR Meter or Impedance Analyzer
The 6223 DC Bias Current Source is designed for performing magnetic saturation current (Isat) and temperature rise current analysis (Irms) on inductors. It provides a single output current of 20A. To conduct such analysis, you have the option to purchase the system along with the 6632 Impedance Analyzer or the 6355/6356 LCR Meter. If you choose the 6632 Impedance Analyzer, it has a frequency range of 100Hz-10MHz and can handle a maximum output current of 120A using 6 units.For the 6355 LCR Meter, it has a frequency range of 100Hz-200kHz and can handle a maximum output current of 120A using 6 units.The 6356 LCR Meter has a frequency range of 100Hz-500kHz and can handle a maximum output current of 120A using 6 units.
Inquiry Compare
DC Bias Current Source|6225 (20A)
DC Bias Current Source
6225 (20A)
  • Up to 30MHz
  • Each individual unit can output DC Bias Current 20A (Max.20A)
  • Control by the LCR Meter or Impedance Analyzer
The 6225 DC Bias Current Source is designed for performing magnetic saturation current (Isat) and temperature rise current analysis (Irms) on inductors. To conduct such analysis, it is necessary to purchase the system along with the 6632 Impedance Analyzer, which has a frequency response range of 100Hz-30MHz and a maximum output current of 20A.
Inquiry Compare
DC Bias Current Source| 6240 (40A)
DC Bias Current Source
6240 (40A)
 
  • Up to 3MHz
  • Each individual unit can output DC Bias Current 40A (Max.320A)
  • Control by the LCR Meter or Impedance Analyzer
The 6240 DC Bias Current Source is designed for performing magnetic saturation current (Isat) and temperature rise current analysis (Irms) on inductors. It provides a single output current of 40A. To conduct such analysis, you have the option to purchase the system along with the 6632 Impedance Analyzer. For the 6632 Impedance Analyzer, it has a frequency range of 100Hz-3MHz and can handle a maximum output current of 320A using 8 units.
Inquiry Compare
DC Bias Current Source|6220 (20A)
DC Bias Current Source
6220 (20A)
 
  • Up to 1MHz
  • Each individual unit can output DC Bias Current 10A (Max.60A)
  • Control by the LCR Meter or Impedance Analyzer
The 6220 DC Bias Current Source is designed for performing magnetic saturation current (Isat) and temperature rise current analysis (Irms) on inductors. It provides a single output current of 20A. To conduct such analysis, you have the option to purchase the system along with the 6632 Impedance Analyzer. For the 6632 Impedance Analyzer, it has a frequency range of 100Hz-3MHz and can handle a maximum output current of 120A using 6 units.
Inquiry Compare
DC Bias Current Source|6210 (10A)
DC Bias Current Source
6210 (10A)
  • Up to 1MHz
  • Each individual unit can output DC Bias Current 10A (Max.60A)
  • Control by the LCR Meter or Impedance Analyzer
The 6210 DC Bias Current Source is designed for performing magnetic saturation current (Isat) and temperature rise current analysis (Irms) on inductors. It provides a single output current of 20A. To conduct such analysis, you have the option to purchase the system along with the 6632 Impedance Analyzer. For the 6632 Impedance Analyzer, it has a frequency range of 100Hz-3MHz and can handle a maximum output current of 60A using 6 units.
Inquiry Compare

Compare