MICROTEST DC Bias Source Test System provides precise verification of magnetic components' magnetic saturation current (Isat) and temperature rise current (Irms). It is equipped with a DC bias current source integrated with an LCR meter/Impedance Analyzer and can be configured as a desktop unit or integrated into a testing cabinet. Operation settings and test results are displayed on the LCR meter/Impedance Analyzer and can also be accessed through PC connection software.

The DC bias current output ranges up to a maximum of 640A/120A/60A/20A, with frequency responses of 100Hz-30MHz/10MHz/3MHz.

For research and development (R&D) or scientific research institutions, there is the option of the 6632+ / 6632S+ series, which includes a current curve sweep analysis feature.

For production lines, the 6350+ series is available as an option.
DC Bias Current Source/System
DC Bias Current Test System|6632+ Series
DC Bias Current Test System
6632+ Series
 
  • Current and frequency graphic scanning analysis
  • Frequency response 100Hz-30MHz /10MHz/3MHz
  • DC Bias Current Output Max.640A/320A/120A/60A/20A
  • DCR Measurement function
  • Built-in the Permeability-μr
  • Long-term consecutive maximum power output
  • Direct Handler interfaces control through Impedance Analyzer
  • Support meter mode and list mode, sweep mode
DC Bias Source Testing System combines the impedance analyzer 6632 with a DC bias source.This system is capable of analyzing the saturation characteristics of inductors, coils, ferrites, and magnetic cores. Additionally, it provides testing for the relative permeability (μr) to analyze key properties of magnetic materials. The system supports magnetic saturation current and temperature rise current scanning analysis, providing research and development engineers with fast and accurate current curve variations. When integrated into a production line, it offers the option of ammeter mode or multi-step mode. Measurement results are displayed numerically, and the system supports PC connectivity for storing test data and conducting report analysis.
Inquiry Compare
DC Bias Current Test System|6632S+ Series
DC Bias Current Test System
6632S+ Series
  • Current and frequency graphic scanning analysis
  • Frequency response 100Hz-30MHz /10MHz/3MHz
  • DC Bias Current Output Max.640A/320A/120A/60A/20A
  • Equivalent Circuit Analysis-6632S
  • DCR Measurement function
  • Built-in the Permeability-μr
  • Long-term consecutive maximum power output
  • Direct Handler interfaces control through Impedance Analyzer
  • Support meter mode and list mode, sweep mode
DC Bias Source Testing System combines the impedance analyzer 6632S with a DC bias source.This system is capable of analyzing the saturation characteristics of inductors, coils, ferrites, and magnetic cores. 6632S supports Equivalent Circuit Analysis with seven different models to assist customers in analyzing the impact of parasitic components on impedance/frequency.The system supports magnetic saturation current and temperature rise current scanning analysis, providing research and development engineers with fast and accurate current curve variations.
Inquiry Compare
DC Bias Current Test System|6350+ Series
DC Bias Current Test System
6350+ Series
  • Frequency Response 100Hz-200k/500kHz
  • Supports maximum output DC bias current of 640A/320A/120A
  • DCR measurement function
  • Can sustain maximum power output for long periods of time
  • Output impedance: 100Ω
  • Open/short circuit calibration function
  • Supports meter measurement mode/multi-step list testing
6355/6356+6243H/6243/6223 provide a frequency response range of 100Hz to 200k/500kHz and a maximum output current of 640A/320A/120A. These systems are used for testing inductors, coils, ferrites, and core saturation currents.
Inquiry Compare
DC Bias Current Source|6243H/6243 (40A)
DC Bias Current Source
6243H/6243 (40A)
  • Up to 10MHz
  • Each individual unit can output DC Bias Current 40A (Max.640A)
  • Control by the LCR Meter or Impedance Analyzer
The 6243H/6243 DC Bias Current Source is designed for performing magnetic saturation current (Isat) and temperature rise current analysis (Irms) on inductors. It provides a single output current of 40A. To conduct such analysis, you have the option to purchase the system along with the 6632 Impedance Analyzer or the 6355/6356 LCR Meter. If you choose the 6632 Impedance Analyzer, it has a frequency range of 100Hz-10MHz and can handle a maximum output current of 640A using 16 units.For the 6355 LCR Meter, it has a frequency range of 100Hz-200kHz and can handle a maximum output current of 640A using 16 units.The 6356 LCR Meter has a frequency range of 100Hz-500kHz and can handle a maximum output current of 640A using 16 units.
Inquiry Compare
DC Bias Current Source|6223 (20A)
DC Bias Current Source
6223 (20A)
  • Up to 10MHz
  • Each individual unit can output DC Bias Current 20A (Max.120A)
  • Control by the LCR Meter or Impedance Analyzer
The 6223 DC Bias Current Source is designed for performing magnetic saturation current (Isat) and temperature rise current analysis (Irms) on inductors. It provides a single output current of 20A. To conduct such analysis, you have the option to purchase the system along with the 6632 Impedance Analyzer or the 6355/6356 LCR Meter. If you choose the 6632 Impedance Analyzer, it has a frequency range of 100Hz-10MHz and can handle a maximum output current of 120A using 6 units.For the 6355 LCR Meter, it has a frequency range of 100Hz-200kHz and can handle a maximum output current of 120A using 6 units.The 6356 LCR Meter has a frequency range of 100Hz-500kHz and can handle a maximum output current of 120A using 6 units.
Inquiry Compare
DC Bias Current Source|6225 (20A)
DC Bias Current Source
6225 (20A)
  • Up to 30MHz
  • Each individual unit can output DC Bias Current 20A (Max.20A)
  • Control by the LCR Meter or Impedance Analyzer
The 6225 DC Bias Current Source is designed for performing magnetic saturation current (Isat) and temperature rise current analysis (Irms) on inductors. To conduct such analysis, it is necessary to purchase the system along with the 6632 Impedance Analyzer, which has a frequency response range of 100Hz-30MHz and a maximum output current of 20A.
Inquiry Compare
DC Bias Current Source| 6240 (40A)
DC Bias Current Source
6240 (40A)
 
  • Up to 3MHz
  • Each individual unit can output DC Bias Current 40A (Max.320A)
  • Control by the LCR Meter or Impedance Analyzer
The 6240 DC Bias Current Source is designed for performing magnetic saturation current (Isat) and temperature rise current analysis (Irms) on inductors. It provides a single output current of 40A. To conduct such analysis, you have the option to purchase the system along with the 6632 Impedance Analyzer. For the 6632 Impedance Analyzer, it has a frequency range of 100Hz-3MHz and can handle a maximum output current of 320A using 8 units.
Inquiry Compare
DC Bias Current Source|6220 (20A)
DC Bias Current Source
6220 (20A)
 
  • Up to 1MHz
  • Each individual unit can output DC Bias Current 10A (Max.60A)
  • Control by the LCR Meter or Impedance Analyzer
The 6220 DC Bias Current Source is designed for performing magnetic saturation current (Isat) and temperature rise current analysis (Irms) on inductors. It provides a single output current of 20A. To conduct such analysis, you have the option to purchase the system along with the 6632 Impedance Analyzer. For the 6632 Impedance Analyzer, it has a frequency range of 100Hz-3MHz and can handle a maximum output current of 120A using 6 units.
Inquiry Compare
DC Bias Current Source|6210 (10A)
DC Bias Current Source
6210 (10A)
  • Up to 1MHz
  • Each individual unit can output DC Bias Current 10A (Max.60A)
  • Control by the LCR Meter or Impedance Analyzer
The 6210 DC Bias Current Source is designed for performing magnetic saturation current (Isat) and temperature rise current analysis (Irms) on inductors. It provides a single output current of 20A. To conduct such analysis, you have the option to purchase the system along with the 6632 Impedance Analyzer. For the 6632 Impedance Analyzer, it has a frequency range of 100Hz-3MHz and can handle a maximum output current of 60A using 6 units.